INTRODUCTION: Objective: This study aimed to evaluate the agreement between arterial blood gas (ABG) potassium measurements and serum potassium levels in patients presenting to the emergency department with acute dyspnea, and to assess whether ABG potassium can serve as a rapid estimation tool in clinical practice.
METHODS: In this retrospective observational study, data from 1,262 adult patients presenting to the emergency department between January 1, 2021, and January 1, 2024 were analyzed. Patients with concurrent arterial blood gas and serum potassium measurements obtained within ≤10 minutes were included. Normality of data distribution was assessed using the Shapiro–Wilk test. Paired statistical analyses (paired samples t-test or Wilcoxon signed-rank test, as appropriate) were performed, and agreement between the two methods was evaluated using Bland–Altman analysis.
RESULTS: No statistically significant differences were observed between ABG and serum potassium levels in hypokalemic, hyperkalemic, and normokalemic groups (p=0.982, p=0.712, and p=0.567, respectively). The overall mean difference between the two methods was 0.04 ± 0.32 mmol/L. Bland–Altman analysis demonstrated a mean bias of 0.04 mmol/L, with limits of agreement ranging from −0.58 to 0.66 mmol/L. Hyperkalemic patients tended to exhibit acidosis, whereas hypokalemic patients showed alkalosis. The differences in acid–base parameters were statistically significant (p=0.001).
DISCUSSION AND CONCLUSION: ABG potassium measurements show a reasonable level of agreement with serum potassium levels and may serve as a rapid estimation tool in emergency settings. However, due to the observed variability, ABG potassium should not be considered a direct substitute for serum potassium. Integration with clinical and laboratory findings remains essential.
Keywords: arterial blood gas, serum, hypokalemia, hyperkalemia, normokalemia